After reading the above, I am curious if multi-path support is available using either 5774 or 5735 HBA? Also, can each IBM i partition have their own set of HBAs and multi-path to the V3700/V7000 direct attached?

Both the 5774 and 5735 support multi-path. The recommended configuration in a fabric attached environment is that each physical port be zoned to a port from each controller.

For direct attached, you can only attach a port to a single controller, but you can still do multi-path by using the other port on the 5774 and attaching it to the other controller.